  • NEC Requirements for Generators and Standby Power Systems
    Mike Holt Enterprises, Inc • www MikeHolt com • 888 NEC CODE (632 2633) 5 NEC Requirements for Generators and Standby Power Systems 445 18 Disconnecting Means Generators must have one or more disconnecting means that disconnects all power, except where: Figure 445–7 (1) The driving means for the generator can be readily shut down, and
  • Gas station wiring requirements | Electrician Talk
    NEC 2017 514 8 Underground Wiring ENHANCED CONTENT Fuel spilled in the vicinity of gasoline dispensers seeps into the ground and could migrate into underground electrical conduits
  • Mike holt - Electrician Talk
    TheNEC also requires certain types of circuits in specific places in addition to the minimum requirements based on the VA per sq ft calculation A dwelling unit kitchen, dining room, breakfast room, pantry, or similar area must have at least two 20A, 120V small-appliance receptacle
  • Continuous Load: what is maximum current - Electrician Talk
    From the 2023 NEC Article 100 Definition: Continuous Load: A load where the maximum current is expected to continue for 3 hours or more 210 20(A) Continuous and Noncontinuous Loads "Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads
  • 80% rule? - Electrician Talk
    80% rule applies to continious loads such as motors, lighting or any load expected to be on 3 hours or more A breaker is rated for 100% of the noncontinious load which may include outlets or other small appliance
  • Inconsistent Confusing Conduit Fill Calculation.
    As I said, according to NEC tables 9-1 and 9-5 1 2" EMT is acceptable I don't believe this is acceptable in this case and I don't think a local inspector or any of my local electricians would think it is even if a logically correct argument can be made to show it is allowed under NEC This is exactly my point
  • 110. 15 High-Leg Marking - Electrician Talk
    Reading the NEC for this is nit picking I have worked with 100's of POCO's, I bet IF you can get a wild leg service they make up the rules NOT at all caring for what the NEC says Argue with the entity providing you power is a fools errand You do what they say, use the colors they say and be happy
  • Usage of flexible cords. - Electrician Talk
    How do you guys interpret the interaction between 400 10 and 400 12 in the nec? If you are connecting a cord and plug machine in a shop, which arguably creates noise and vibration, are you allowed to disregard 400 12 which states you cannot have cord run through a drop ceiling? I know I wouldn't do it myself, but this section of code is very vague
  • Stapling Romex - Electrician Talk
    And what code ref did this inspector use to justify his action? Let me guess, none We have a good system, if it needs correcting, the inspector files a form with the state The state sends me a fix it ticket that tells me the NEC section that I violated I have 14 days to correct and send the form back signed
  • Ground rod horizontal in ditch - Electrician Talk
    NEC requires that rods pipes plates and rings all be buried 30" under There's an exception for rods when you hit rock but that's what the OP's talking about, requires 30" deep too (250 52 and 250 53)