英文字典中文字典


英文字典中文字典51ZiDian.com



中文字典辞典   英文字典 a   b   c   d   e   f   g   h   i   j   k   l   m   n   o   p   q   r   s   t   u   v   w   x   y   z       







请输入英文单字,中文词皆可:

respirable    


安装中文字典英文字典查询工具!


中文字典英文字典工具:
选择颜色:
输入中英文单字

































































英文字典中文字典相关资料:


  • MV cable terminations and shield grounds | Information by Electrical . . .
    You would want to maintain the equivalent cross section of the shields That information is usually available from the manufacturer If you have triple ground wires with a three condcutor cable, it is sufficient to connect the splice kits shield terminator to the ground conductor right at the breakpoint of the jacket and carry the three grounding conductors and connect it ti your ground-bus
  • Where should we Terminate the Cable Shields ? - Inst Tools
    A shielded cable is an electrical cable of one or more insulated conductors enclosed by a common conductive layer The shield may be composed of braided strands of copper (or other metal, such as aluminium), a non-braided spiral winding of copper tape, or a layer of conducting polymer Usually this shield is covered with a jacket The shield acts as a Faraday cage to reduce electrical noise
  • Terminating Variable Frequency Drive (VFD) Cables
    Terminating Copper Braid and Copper Tape Shields These shields may be terminated with either a cable gland, or if used in conduit a termination kit Both methods are described below Both ends of the VFD cable need to be terminated in order to allow the high frequency common mode current to flow back through the shield to the drive1
  • Shield Termination Assembly Procedure - Glenair
    7 Serial Number 8 Tension Release Lever Prepare Cable Braid for termination process NOTE: Complete banding on an unfixtured cable assembly Terminating a band to a clamped or fixtured cable will affect the applied forces and interfere with the cut-off operation The cut-off operation causes a rotation of the band termination in order to lock
  • Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
    Terminating Unarmored Variable Frequency Drive (VFD) Cables Foil-Braid or Copper-Tape Shield Constructions Belden VFD Cables are designed for quick and easy termination bles with either foil-braid or copper-tape shield constructions The instructions cover the termination of the cables in external and self-contained enclo
  • 298 | Terminating Shielded Cable - High Performance Academy
    Summary Shielded cable is a critical element in protecting mission critical signals from electromagnetic interference In order for the shield to do its job, we’re going to need to terminate one end so it can drain to ground In this webinar, we’ll look at the options available and demonstrate how it's done
  • Tips for Properly Terminating VFD Cable - Belden
    This also allows the cable to release EMI in the enclosure and in close proximity to potentially sensitive equipment And one more—braided VFD cables are excellent, but one needs to remember not to cut off the braid at the termination point This can reduce the connectivity of the ground path
  • How to Terminate Braided Sleeving – CableOrganizer
    OPTION 1 — TERMINATE WITH TAPE This is the most economical and least time-consuming method for terminating braided sleeving The only supplies required are color-matching electrical tape and a pair of scissors After you've run your wires or cables through braided sleeving, simply wrap the ends tightly with electrical tape
  • Termination Grounding Kit
    1 4 Position the pre-formed "U" shaped high-amp ground braid over the metallic shield with tails extending over the cable jacket as shown The solder block must be centered over the previously applied mastic strip Secure one tail to the cable jacket with a vinyl tape marker located 4 1 2" (114 mm) from the edge of the cable semi-con
  • Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
    Do I terminate the shield at both ends? Drive cable shields should always be terminated at the motor and at the drive Intermediate termination of the ground or shield is not recommended The shield acts as a conductor for common mode current containment Failure to terminate the shields and grounds properly could result in harmful electrical noise or destructive common mode currents flowing





中文字典-英文字典  2005-2009